It is a pH/ORP indication and adjustment meter fit for on-site use that has pump control functions using voltage-applied contact signals.
Without the need to provide a control panel, cost reduction can be realized.
・The automatic control method can be chosen among 3 types.
・With the temperature compensation being chosen among 3 types, the meter is ready for use with sensors of various manufacturers.
・The meter is equipped with input functions such as the power switch, level gauge, etc. of a mixer, pump, etc. as the standard functions.
・Indication with a large LCD.
・The meter can be installed outdoors such as in a site.
・Automatic calibration functions that are also ready for use with overseas buffer solutions.
・Can be connected to a computer by RS485 output.
・In addition to the measurement and indication of the pH meter/ORP values, the current values of transmission output can also be indicated.
・pH neutralization or oxidation/reduction treatment of drainage in the chemical industry, etc.
・Incorporation of the apparatus of each process.
・pH measurement and control in hydroponic culture, etc.
・pH measurement and control of drainage from cleaning.
・pH measurement and control for drainage from
Name | pH meter/ORP meter with control functions | |
Type | PET-M3P | |
Indication | Digital LCD | |
Range of measurement | pH:0.00~14.00 ORP:-999~+999mV | |
Resolution | pH:0.01pH ORP:1mV | |
Temperature compensation | Automatic temperature compensation Temperature compensation range:0 - 100℃ (temperature indication can be chosen) | |
Temperature compensation element | 6.8kΩ、500Ω、Pt1000Ω | |
Calibration | Automatic calibration | With automatic calibration solution judgment functions pH6.86 and either pH4.01, 9.18 or 1.68 (JIS) pH7.00 and either pH4.00 or 10.00 (USA) |
Manual calibration | pH6.86, 7.00 and solutions that differ from them by 2pH or more | |
Control output | Control equipment: pump, etc. 2 units (automatic, manual) mixer, etc. 1 unit (automatic, manual), mixer, etc. 2 units (manual) * Maximum load capacity: 100VA each (inductive load) voltage-applied output | |
Control method | Pump control (ON/OFF; time division proportional; twin timer) Pump automatic (external signal input) Mixer automatic (external signal input) | |
Control input | Voltage-applied (1 point); no-voltage contact (3 points); hold contact (for holding measured values) | |
Transmission output | 4 - 20mADC (maximum load resistance: 500Ω) *Indication of current value can be chosen | |
Communication | RS-485 | |
Power supply | AC100-240V±10% (single phase, 50/60Hz) | |
Power consumption | 10VA (at no load) | |
Construction for protection | Drip-proof construction: IP54 or equivalent (when using sunshade cover) | |
Dimensions | 138(W)×138(H)×174(D) mm | |
Weight | About 2kg | |
Standard optional item | Sunshade cover |