The easy-to-see and large LCD with backlight indicates the EC measurement value,
control point, control direction, whether control is done or not, current value,and temperature.
・Large LCD indication with backlight.
・Provided with the scaling functions of DC4 - 20mA in transmission output, connection can be made to a wide range of external equipment.
・Provided with ON/OFF control and twin timer control, the meter is fit for control in various places.
・With a built-in 24-hour timer. Irrespective of the conductivity, ON time and OFF time settings and control of the number of times can be made, thereby capable of being utilized in various applications.
・Having a built-in zone alarm interconnected with conductivity, an out-of-range alarm is output as an output at one point.
・The meter has 2 ranges of conductivity measurement: 2000μS/cm and 20.00mS/cm, and a switching between /cm and /m can also be made.
・As for the electrode, the alternating current 5-electrode method is employed that is resistant to dirt and involves little measurement error.
・Titanium is used for the detection electrode, and PVC is used as the body material, thus having excellent corrosion resistance.
・The power supply is designed to work at any voltage between AC100 and 240V.
・The outline is compact, with the dimensions of 96W×96H×145D. (DIN96)
・Nutrient solution control in a plant factory.
・Nutrient solution measurement and control in hydroponics (a hydroponic greenhouse).
・Replenishing water control for a cooling tower.
Name | High concentration conductivity adjustor |
Type | CEH-21 |
Method of measurement | Alternating current 5-electrode method |
Range of measurement | Conductivity range 0 - 20.00mS/cm, 0 - 2000μS/cm Manual switching /cm, /m Switchable Conversion at the reference temperature 25℃ |
Temperature compensation | Temperature compensation range: 0 - 50℃ Temperature accuracy: ±1℃ Temperature element Pt1000Ω Temperature compensation coefficient Automatic: 2%/℃ Manual: 0.5-5%/℃ |
Resolution | EC:0.01mS/cm、1μS/cm |
Transmission output | DC4 - 20mA(maximum load: 500Ω) With scaling functions |
External input | No voltage contact input 2 points |
Control method | ON/OFF control Twin timer control ON time: 599sec OFF time: 599sec 24Hr timer interlock ON time/OFF time, Number of times(within 24 hours) |
Setting method | Conductivity interlock(ON/OFF control, twin timer control) 24Hr timer interlock ON time/OFF time, Number of times(within 24 hours) Conductivity interlock zone alarm Above to be chosen for each pump |
Control output | No voltage contact output AC 240V 3A 2 points |
Power supply | AC100~240V |
Operating environment | 0 - 40℃ 85%RH or less |
Outer dimensions | 96(W)×96(H)×145(D) mm |
Weight | About 1.0kg |
Standard accessories | Main body attachment tool, front cover |
Optional item | FCS-75N |
Name | EC electrode |
Type | FCS-75N |
Cell constant | 1.0(at standard) |
Material | Detection electrode:Ti Body:PVC |
Lead length | 10m |